Labsphere’s LMS-3M Three Meter Lamp Measurement Sphere

With lighting technology advancing to include larger and more complex devices, Labsphere has introduced the LMS-3M three meter integrating sphere for complete optical characterization of these larger lamps and luminaries.

LED professional Editors

LED professional

The sphere complies with IESNA LM-79 and LM-80 standards to deliver accurate and reproducible measurements of any lamp, up to 2m linear lamps and 30cm luminaries.

The three meter lamp measurement integrating sphere accommodates light sources positioned base up, base down, or longitudinally, to easily and efficiently measure virtually any lamp type, including fluorescents up to 2m in length. The design also allows for forward and partial flux measurements of test sources that are board mounted or heat-sinked.

The larger sphere better integrates light for more reliable testing of a device’s photometric and colourimetric performance with measurements of Total Spectral Flux, Luminous Flux, Correlated Colour Temperature (CCT), Colour Rendering Index (CRI), and Chromaticity. Measurement data relies only on the test device’s true power, not on the size, shape, or spectral distribution.

The near-Lambertian properties of the sphere’s Spectraflect® interior coating provide a uniform dispersion of light that integrates and reduces hotspots better than other available sphere coatings materials. Spectraflect exhibits reflectance values of 98% and is spectrally flat through the visible spectrum for higher optical efficiency on low lumen lamps.

The LMS-3M is designed to measure a variety of lamps and luminaires on the same system with little adjustment. The standard sphere geometry accommodates 4pi measurement, and with optional aperture reducers, can easily be configured for 2pi measurement. Baffled intake and output ports and an ambient air temperature controller maintain and monitor the temperature inside the measurement environment, complying with Energy Star requirements. The new sphere size fully integrates with all Labsphere photometric and spectroradiometric systems and software so current system users may upgrade easily.

The LMS-3M can be customized with the software and accessories to fit testing needs. To speak to an experienced applications engineer about unique applications, send an e-mail to labsphere@labsphere.com, or phone +1 (603) 927-4266.

About Labsphere:
Labsphere (www.labsphere.com), a Halma company, is a world leading designer and manufacturer of precision radiometric and photometric test and measurement products addressing the specific needs of the aerospace, electronic imaging, LED, lighting, medical imaging and optics industries. The company offers a broad line of integrating sphere systems, uniform calibration sources, spectroscopy accessories and diffuse reflectance materials and coatings.

Did you like this article?

Share this article

You could also like this

Testing

Robots on the pitch: how to measure sports lighting in the field

Part II of Octavio L. Pérez's series on measuring sports lighting. It explains which illuminances are measured on a football pitch – horizontal at ground level, vertical at 1.5 m and towards the TV cameras – and how GNSS and robots speed up a FIFA 96-point survey with 480 readings: grid marking drops from 90 to about 30 minutes, and a rover measures the points in 40 minutes instead of 75.

Testing

Why detecting defects in LED light modules matters

The latest episode of the LED professional podcast looks at automated LED testing in lighting manufacturing. As LED modules move to higher densities and multi-die designs, manufacturers face growing demands for consistent quality, optical performance and reliability, while production has to stay efficient and cost-effective. The episode explains how automated testing detects defects, measures optical performance, improves production efficiency and reduces quality-related costs. It also takes a closer look at the T100L automatic LED tester from SPEA (Volpiano, Italy), whose fiberless testing technology addresses the limitations of conventional testing methods and is designed for greater flexibility, accuracy and throughput. A seven-minute episode, released on 14 November 2026.

Testing

Glamox opens new laboratory and research facility in Poland

Glamox has opened a new laboratory and research facility near its Dobczyce manufacturing site in Poland to centralize product testing, research and compliance for building, marine and Ex lighting products.

Testing

Automotive LED Light Testing: From Design Trends to Zero Defects Manufacturing

The automotive industry is undergoing a lighting revolution. Driven by design freedom, lighting has evolved from a basic safety necessity into a core element of vehicle identity, passenger experience, and external communication.

Luminuscree ledEdison optoTE connectivityLTF TechnologyLoreos

The latest Press Releases

Explore All

Stay current with our monthly Update from the lighting industry

LEDprofessional Newsletter

You will receive a confirmation e-mail. Unsubscribe anytime.