McLED

Testing

Robots on the pitch: how to measure sports lighting in the field

Part II of Octavio L. Pérez's series on measuring sports lighting. It explains which illuminances are measured on a football pitch – horizontal at ground level, vertical at 1.5 m and towards the TV cameras – and how GNSS and robots speed up a FIFA 96-point survey with 480 readings: grid marking drops from 90 to about 30 minutes, and a rover measures the points in 40 minutes instead of 75.

LED professional Editors

Multi-sensor illuminance measuring head on a tripod on a floodlit football pitch
Multi-sensor illuminance measuring system on a football pitch, as used for FIFA floodlight tests. (Image: Octavio L. Pérez) · Photo: © Octavio L. Pérez

This article by Octavio L. Pérez, Ph.D, FIFA Approved Floodlights Technician and Integrative and Sports Lighting Research Scientist & Consultant, is the second part of his series on illuminance measurements in sports lighting, written for LED professional Review (LpR) in 2026. Part I covered the illuminance meter and its limitations.

In a previous article we reviewed the illuminance meter (luxmeter) and its limitations in sports lighting illuminance assessment. That article was more related to the technicalities and fundamentals of the instrument.

In this piece, we will review the applications of the luxmeter in the field, in sports lighting, and how the accomplishment of different measurements (horizontal, vertical, camera) has different approaches – one does not fit all.

Even if illuminance is the measurand of choice, we have to keep in mind its limitations, as eyes and cameras perceive luminance, that is more complex to measure and evaluate.

Illuminance in sports lighting – horizontal (Eh) and vertical (Ev)

We have two (2) main illuminances to assess in sports lighting, particularly for football/soccer:

  • Horizontal (Eh)
  • Vertical (Ev)

In the case of vertical measurement of illuminance (Ev), we have to distinguish between two main approaches:

  • Orthogonal Planes related to the play area (PA): Ev_00, Ev_90, Ev_180, Ev_270
  • Camera Planes (measurement planes normal to the cameras)

About the heights, following international standards, such as EN 12193 (Europe) and AS2560 (Australia), Eh is taken at ground level and Ev at 1.5 m (same as for glare calculations) with some exceptions.

The reason for these criteria makes sense. In the case of Eh, this is the illuminance that reaches the playground, the surface that the cameras are going to capture, and the ball and boots in the case of sports such as football/soccer. For Ev, it is the average height of the upper side of the body and arms of the players. Think about the differences between sports such as football/soccer and basketball.

There are private standards that do both measurements (Eh and Ev) at the same height, based on reasons of practicality. Rather than doing one pass at ground level and another pass at 1.5 m, it is much easier, and cheaper, to do a single pass at 1 m. The practicality justification is that Eh at ground level and Eh at 1 m do not differ “significantly”, assumption that is fundamentally wrong, getting real differences in the sidelines (Ehg < Eh1 m) and in the middle of the field (Ehg > Eh1 m).

As a “curiosity”, even if this is a disregarded detail in sports lighting, we also have to consider that simulations (“Modelled Performance”) are calculated assuming that the pitches are flat. This can be the situation for indoor spaces, but definitely not for outdoor pitches. Depending on the weather/rain and drainage systems, outdoor pitches can have slopes that will affect the lighting, with height differences between the center and the sides of the pitch (“crowning”). Nevertheless, this is out of the scope of this article.

Let’s go deeper on each of the illuminances (Eh and Ev) before entering into automation/robotics details.

Horizontal illuminance at ground level (Ehg)

Horizontal illuminance measurement is the historical foundation of sports lighting.

The main aim of Eh is to assess the uniformity levels that reach the playing surface (ground). Factors such as the reflectance of the ground material play a critical role, and we can end up seeing dark spots in places of maximum illumination, as the “brightness” that we perceive is not illuminance but luminance (reflected light). Nevertheless, luminance measurement has its own complexities, and Eh assessment has been in place for years, acting as an acceptable “proxy”.

The measurement of horizontal illuminance (Eh) at ground level (Ehg), is one of the more hated ones by operators. The reasons are easy and understandable:

  • First, it is about ergonomics: you need to lean forward to put the instrument on the ground. At one point nothing to worry about, but when you have to do it around 100 times, at night, in a humid environment, your back will start to resent it.
  • Second, proper leveling of the instrument. It is very easy in indoor surfaces, such as basketball courts, and a bit tricky when you go into grass surfaces, and even more on natural grass. The orientations of the grass fibers can take the instrument out of level, and solutions such as a plates are needed to ensure proper leveling of the meter.
  • Third, distancing from the measurement. In order to avoid interfering with the reading, you need to move away from the instrument.

The effect of f2 (cosine factor) that we discussed in the previous article has minor impact in Eh on the sidelines (with a near perpendicular angle of attack from the fixtures) vs on the middle of the pitch where the angles can become substantial, particularly with lower heights of the fixtures structures (poles), entering the cosine law into (negative) effect.

Vertical illuminance – orthogonal planes (0º, 90º, 180º, 270º)

Orthogonal planes are relatively easy to handle, particularly on rectangular pitches. The main reference 0º is usually one of the long sidelines (‘01’-‘12’ in the case of FIFA/UEFA). From there you get the other ones rotating clockwise ninety degrees to get 90º, 180º, and 270º. There are three basic approaches for this mission:

  1. If you have only one meter, you will need to do four (three + 1) rotations (0º, 90º, 180º, 270º), this means four uncertainties related to orientation, and only one to the instrument.
  2. Having two meters makes life easier. Starting with one meter at 0º and another one at 180º on a supporting structure, a single rotation (actually two as you have to go back to 0º) saves time and reduces orientation uncertainties, yet increases uncertainties with the meters, as we now have two in action.
  3. Four meters to catch the illuminance in the four orthogonal planes at once is the simplest one in terms of operation as no rotation is needed. Here, the position of the four meters in the supporting head is critical, and once you have it, nothing needs to be modified. The only challenge is to level and aim properly at each point, that was also in the previous ones. The main disadvantage is the four uncertainties of the four meters, that need to be considered individually. And this also means four calibrations rather than one.

Illuminance to cameras (Ecam)

Ecam adds complexity to the assessment. One of the most demanding standards is the one from “LaLiga” in Spain, a private standard where Ecam shall be taken against (normal to) four (4) reference cameras all over the pitch: master, opposite master, and goals (goals measurements are taken only for half pitch) (Figure 1).

Figure 1: Measurement geometry with four reference cameras: Ecam towards master and goal cameras, Eh and Ev at a grid point (left); measuring heads at a corner of the pitch (right). (Image: Octavio L. Pérez)

This means that working with more than one (1) sensor is not an advantage anymore, as it was the case for orthogonal Ev. Here, on each point, we have to aim the sensor at each of the four (4) cameras. The azimuth (absolute and relative) and elevation change, and no static sensor arrangement solves the situation.

Measurements automation

We previously discussed the need to automate the readings from the luxmeters, and here we will discuss how to automate the pitch assessment, the mission.

Automatic reading from the meter is a must. Consider the FIFA-96 points grid plan, with 5 readings per point (Eh + 4xEv), this means 480 readings, in the field, at night, with humidity and low temperatures – 480 opportunities for failure.

And automation does not stop there. The whole process can be improved and reengineered. Let’s go there.

The grid

The first automation has to happen related to the grid plan. In football/soccer, the most demanding measurement grid plan is the FIFA-96, with 96 points covering the four sidelines. On average, manually measuring the pitch and marking the 96 grid takes between one hour and ninety (90) minutes.

“If” there is good GNSS/GPS coverage on the pitch, marking can be fast. Walking the long sideline takes around 80 seconds, and 50 for the short ones (for an average 105 x 68 meters football/soccer pitch). Doing the math (80 x 8 + 50 = 690 seconds of walking + 10 per point for marking) takes you down from 90 minutes to around half an hour, this means one hour less. This requires a RTK (“Real Time Kinematics”) GNSS (“Global Navigation Satellite System”) with local real-time NTRIP corrections, and an experienced technician.

The density of the grid (number and points distribution) is also going to affect the assessment. Figure 2 shows the same field with a French FFF_25 grid plan. The main risk of this simplified grid, used for low categories and/or training pitches, is that engineers design against the grid for compliance, particularly the cheap manufacturers, and the pitch lighting ends up in a mess even if the lighting design complies with the standard.

Note that the FFF_25 grid (maillage) plan includes ten (10) safety points, in red, to check that the lighting levels in the outer side of the sidelines have at least seventy five percent (75%) of the illuminance of the neighbor points. Here only Eh at ground level is assessed.

Figure 2: The French FFF_25 grid plan on a stadium pitch, with the ten safety points outside the sidelines in red. (Image: Octavio L. Pérez)

Grid path/routing

And here is the next point. Again, “if” GNSS coverage is good, we have the option to move the measuring system with a robot and/or a drone.

Figure 3: Grid path/routing. (Image: Octavio L. Pérez)

Eh automation

For Eh, the rover (terrestrial robot) is a must. A drone is not appropriate for ground level measurements of light. See the pictures of the systems that have been developed that can carry one or more Eh sensors, with and without leveling compensation. Eh is quite easy as orientation (yaw) does not affect the measurement, only the appropriate level (pitch and roll). If level is a must, as it happens on natural turf, then compensations mechanisms must be arranged, being the easiest one a motorized (servos) head. With a rover moving at around 50 cm/sec we need around fourty minutes to do the whole grid coverage including the measurement stops and leveling adjustments. By hand this takes around 45 seconds per point in the best case, going up to around 75 minutes (1h and 15 minutes), plus it is easier on your back!

Figure 4: For Eh, the rover (terrestrial robot) is a must. (Image: Octavio L. Pérez)

Figure 5: Planned path of the rover across the measurement grid, lane by lane. (Image: Octavio L. Pérez)

Ev automation

For Ev automations, with the automated system that I assembled for IGOID-UCLM for the FIFA Floodlights Test Event in Morocco on 2026-02-12 (Figure 6), with seven (7) light sensors, and wireless automated acquisition, timing was reduced to a maximum of 35 seconds between points (depending on time for leveling) and took around one hour, and I successfully passed the FIFA Floodlights test event for IGOID.

Automating the movement of a rover 1m or 1.5m above the ground becomes a bit challenging. The inertia that a sensor head develops at that height requires either low speed of the robot and/or a big platform. For this purpose, the manual movement of the sensor system is a reasonable option.

The issue comes with the measurement of Ev at different heights, such as the 1m (for FIFA/UEFA), the 1.5m for EN-12193. Measuring only at one height is not because of being the most appropriate, but because of simplifying the surveyor’s work. In earlier times this could have been understandable but today it is questionable. Having the drone technology in place, we have to study if taking more than one height for Ev makes sense as the game takes place at different heights depending on the sport. The same thing happens with Eh that has been taken at only one height. Should we take Eh at the height of Ev so that the modelling index could be evaluated at different heights? Think about basketball where part of the game happens at shoulder heights compared to football where most of the game happens at boots height.

Figure 6: Wireless system for illuminance assessment in sport lighting. (Image: Octavio L. Pérez)

Ecam automation

For this particular case, Ecam, the author has developed a patent pending system that automatically points the sensor (illuminance or spectral) to each of the four cameras. Fine adjustments can be made to perfectly target the TV camera without human intervention. The system also reads Eh at 1.5 m in order to estimate the modelling index at each point for each camera. In this case, Eh is not the normal to the ground, but the perpendicular to the normal to the camera.

Conclusion

Sports lighting is a multidisciplinary art and science that highlights the difference between lighting design and illuminating engineering.

A critical part that does not happen in other lighting disciplines except in disciplines such as tunnel lighting, road/street lighting and office lighting is the thoughtful assessment of the lighting delivery.

The main measurand is illuminance, with derived ones such as uniformity, gradient and modelling.

The meter’s limitations are critical and the automation of the reading of the instrument is a must to minimize human errors.

Next step is the automation of the grid ‘walk’-through. In case of Eh at ground level, this is a must that can be accomplished with a rover. In the case of Ev and Ecam this is a more complex task as inertia is generated with height. The automated reading with a full sensor system or robotized one for Ecam is a good alternative that saves a lot of time.

The missing one is the drone for Ev, a system that I have under development, with all the software already operational.

In our next article, we will review the paradigm shift that we are envisioning, with the development of a whole ecosystem, where the skilled technician does not have to be present on the ground, but monitoring the whole process remotely in real-time. Stay tuned.

About the author

Dr. Octavio L. Pérez.

Dr. Octavio L. Perez is a passionate professional, researcher and scholar who contributes to exploring, developing and bringing to the real world the benefits of light and lighting for human wellbeing and wellness, and ultimately, health. He works internationally as an independent consultant, focused on translational research in human centric lighting (HCL), more precisely “integrative lighting”. Dr. Perez is a researcher at Mount Sinai Hospital in NYC, NY, USA. and serves in several international technical committees. He is also a WELL AP (WELL Building Standard Accredited Professional), focusing now in the challenging field of lighting assessment in sports venues. And he has started his second Doctorate focused in this field of lighting (Sports), related to new challenges for Broadcasting requirements and Audit/Survey methodologies.

octavio.perez@lighting.consulting · linkedin.com/in/LightHealth · www.lighting.consulting


Source: Octavio L. Pérez, “Illuminance Measurements in Sports Lighting – Part II, Field Assessment and Robotics”, written for LED professional Review (LpR), 2026. More from the author: www.lighting.consulting. Images: Octavio L. Pérez.

Did you like this article?

Share this article

You could also like this

Testing

Why detecting defects in LED light modules matters

The latest episode of the LED professional podcast looks at automated LED testing in lighting manufacturing. As LED modules move to higher densities and multi-die designs, manufacturers face growing demands for consistent quality, optical performance and reliability, while production has to stay efficient and cost-effective. The episode explains how automated testing detects defects, measures optical performance, improves production efficiency and reduces quality-related costs. It also takes a closer look at the T100L automatic LED tester from SPEA (Volpiano, Italy), whose fiberless testing technology addresses the limitations of conventional testing methods and is designed for greater flexibility, accuracy and throughput. A seven-minute episode, released on 14 November 2026.

Testing

Glamox opens new laboratory and research facility in Poland

Glamox has opened a new laboratory and research facility near its Dobczyce manufacturing site in Poland to centralize product testing, research and compliance for building, marine and Ex lighting products.

Testing

Automotive LED Light Testing: From Design Trends to Zero Defects Manufacturing

The automotive industry is undergoing a lighting revolution. Driven by design freedom, lighting has evolved from a basic safety necessity into a core element of vehicle identity, passenger experience, and external communication.

Testing

CIE Launches Two Advanced Tutorials on Measurement Uncertainty and LED Reference Spectra

The International Commission on Illumination (CIE) has announced two specialized tutorials taking place in September and November 2026, offering lighting professionals, metrology experts, and researchers an opportunity to deepen their knowledge of modern photometric and radiometric measurement…