UV / IR

Precise Measurement of UV Light Sources for Disinfection

UV radiation encompasses a very wide wavelength spectrum between 10 and 400 nm and is subdivided in ISO Standard 21348 into three ranges. The UVC range between 100 and 280nm is currently extremely relevant for air and water disinfection for combating COVID-19. Since the outbreak of the pandemic…

Published by LED professional ·

LED professional

The UVA range lies between 315 and 400 nm. Typical applications are UV curing and UV ink printing. Light sources in the UVB range between 280 and 315nm are used for medical skin treatment. According to their specific field of application, all UV light sources must be precisely measured in terms of radiant flux. This calls for particularly sensitive and reliable measuring equipment.

Instrument Systems offers a complete portfolio for the measurement of UV light sources consisting of high-precision spectroradiometers with very low stray light, PTFE-coated integrating spheres and special calibration standards for the three UV ranges A/B/C.

The most important field of application for UV-LED calibration standards is the monitoring and calibration of UV integrating spheres to radiant flux. With its new ACS-570-UV series, Instrument Systems is the first company in the world to develop temperature-stabilized UV-LED calibration standards that feature radiant flux calibration traceable to the PTB. The ACS series of UV-LED calibration standards is available for the typical peak wavelengths of 280nm (UVC), 305nm (UVB) and 365 nm (UVA). The temporal stability of their radiation is exceptionally good and lies at about 0.2% in 12 hours or 1% in 100 hours.

For calibration to radiant flux, an absolute calibration value traceable to a national institute must be available. Hitherto, neither the PTB nor NIST were able to offer such a value for the UVB and UVC ranges. Consequently, Instrument Systems implemented this radiant flux calibration itself. The traceability of UV-ACS to radiant flux is achieved by extremely precise calibration of the spectrometer optical probes used to the irradiance and integrative measurement with a goniophotometer. The extremely low measurement uncertainties (k=2) of only 4.5% (UVC), 3.5% (UVB) and 2% (UVA) for the UV-ACS are comparatively low as in the metrologically unproblematic visible range. With this achievement, Instrument Systems has earned a worldwide position as pioneer in radiant flux calibration in the UVA, UVB and UVC range.

https://www.instrumentsystems.com/en/applications/uv-leds/

About Instrument Systems GmbH
Instrument Systems GmbH develops, manufactures and markets turnkey solutions for light measurement. Its main products are array spectrometers, imaging photometers and colorimeters. Key applications are LED/SSL and display measurement, as well as spectroradiometry and photometry. Products of the Optronik line for the automotive industry and traffic technology are developed at the Berlin facility. Since 2012 Instrument Systems has been a wholly owned subsidiary of the Konica Minolta Group.

For further details refer to:
Instrument Systems Optische Messtechnik GmbH, Kastenbauerstr. 2, 81677 Munich, Germany

Phone: +49-89-454943-0, E-Mail: sales@instrumentsystems.com

Website: www.instrumentsystems.com

Did you like this article?

Share this article

You could also like this

UV / IR

Far-UVC LEDs transmit data at record speed | Ferdinand-Braun-Institut

Researchers at Ferdinand-Braun-Institut (FBH), the University of Strathclyde, and the University of Cambridge demonstrated wireless optical communication using far-UVC LEDs at wavelengths below 235 nm, achieving data rates up to 1.5 gigabits per second over a 30 cm line-of-sight link. The FBH-developed LEDs are optimized for high optical power and fast modulation by segmenting the emitting surface to reduce capacitance and increase current density. Far-UVC offers low solar background outdoors and stronger Rayleigh scattering for potential non-line-of-sight links. Next steps include testing longer distances, non-line-of-sight performance, and environmental effects on transmission.

UV / IR

PureFize Presents Field-emission Cathodoluminescent Approach for Next-generation Far-UVC Devices

Swedish UV technology company presents breakthrough results showing deep-UV emission below 240 nm from a scalable, phosphor-tunable device platform.

UV / IR

Violumas Has Launched New 255nm, 265nm, and 275nm LEDs

Violumas, provider of high-power UV LED solutions and inventor of 3-PAD LED technology, has released its next-generation 255nm, 265nm, and 275nm LEDs in both SMD and COB configurations.

UV / IR

LEDINTRO Introduces Breakthrough Harmless 230nm UV LED Air Sterilization Ball

Ultraviolet radiation has long been recognized as an effective method for inactivating airborne and surface-borne microorganisms. However, the widespread use of conventional UV-C sources has been constrained by safety concerns, as prolonged human exposure to traditional germicidal wavelengths is…

LuminusEdison optoLTF TechnologyLoreos

The latest Press Releases

Explore All

Stay current with our monthly Update from the lighting industry

LEDprofessional Newsletter

You will receive a confirmation e-mail. Unsubscribe anytime.